TLG Series Tension Links
Designed for electronic measurement of cable tension of up to 5,000 lbs, the TLG load cell may be used in either in-line or over-the-sheave configuration.
|
Options: • Aluminum or Stainless steel • Internal cal resistor • Range: 0-5,000 lbs • LED display
Specifications: • Max excitation voltage: 15Vdc • Output: 2 - 3 mV/V ±10% standard, available to ±1% • Overload: 50% over rated capacity without zero shift • Nonlinearity: less than 0.15% FSO* • Hysteresis: less than 0.1% FSO • Non-repeatability: better than 0.05% FSO • Thermal zero shift: less than 0.002% per º F • Thermal span shift: less than 0.002% per º F
* BFSL
| Designed for electronic measurement of cable tension of up to 12,500 lbs, the TLG load cell may be used in either in-line or over-the-sheave configuration.
|
Options: • Aluminum or stainless steel • Internal cal resistor • Range: 0-12,000 lbs • Internal signal conditioning • LED display
Specifications: • Max excitation voltage: 15Vdc • Output: 2-3 mV/V standard ±10% standard available to ±1% • Overload: 50% over rated capacity without zero shift • Nonlinearity: less than 0.15% FSO* • Hysteresis: less than 0.1% FSO • Non-repeatability: better than 0.05% FSO • Zero balance:within ±2% FSO, available down to ±0.5% • Thermal zero shift: less than 0.002% per º F • Thermal span shift: less than 0.002% per º F
*BFSL
| Designed for electronic measurement of cable tension of up to 25,000 lbs, the TLG load cell may be used in either in-line or over-the-sheave configuration. The unit to the right has greater than 100.000 lbs in ultimate tensile strength.
|
Options:
• Aluminum or stainless steel • Internal cal resistor • Range: 0-25,000 lbs • Internal signal conditioning • LED display
Specifications: • Max excitation voltage: 15Vdc • Output: 2-3 mV/V standard ±10% standard available to ±1% • Overload: 50% over rated capacity without zero shift • Nonlinearity: less than 0.15% FSO • Hysteresis: less than 0.1% FSO • Non-repeatability: better than 0.05% FSO • Zero balance: typically within ±2% FSO, available to ±0.5% • Thermal zero shift: less than 0.002% per º F • Thermal span shift: less than 0.002% per º F
*BFSL |
|
|